• QUESTIONS? GIVE US A CALL! 1 (630) 655-3900

Navigate to the Occupational Training & Supply Inc. homepage

NEXT DAY DELIVERY
Only in Willowbrook surrounding areas

Home > Supplies > Spray Foam Insulation

Spray Foam Insulation

New state regulations are in effect for certain materials used in Versi-Foam Systems original formula. Affected states must purchase the Low GWP (HFO) Formula.

For more information about the AIM Act click
here

State Phase-Down of Climate-Damaging Hydrofluorocarbons
In May 2021, the U.S. Environmental Protection Agency (EPA) announced that it would be “proposing its first rule [to] phase down the production and consumption of hydrofluorocarbons (HFCs), highly potent greenhouse gases commonly used in refrigerators, air conditioners, and many other applications.”
The final rule of the new regulation under the American Innovation and Manufacturing (AIM) Act sets baseline levels for HFC production and consumption, from which reductions will occur. This “establishes an initial methodology for allocating and trading HFC allowances for 2022 and 2023, and creates a robust, agile, and innovative compliance and enforcement system,” as stated by the EPA.
Before the official ruling took hold, some states already ruled to stop the manufacturing and use of products containing HFCs, including spray foam insulation. As such, Versi-Foam® created a new formula that uses hydrofluoroolefins (HFOs), a blowing agent that has a lower global warming potential (GWP).

For an updated list of states, check here
While the cost to manufacture this material is higher, its price should come down over time as more states put into place this new regulation and more companies begin to produce HFOs. Be sure to check your local regulations to make sure you order the right product for your area. No matter where you live, Versi-Foam®’s environmentally-friendly products are energy-efficient, LEED-certified, and readily available to you.

If ordering more than three units of the System 15 or more than two units of the System 50, they will be arriving on a truck.

Filters

Filters

Sort By:
Products per page

Spray Foam Insulation

    Versi-Foam - Hy Flo 700
    RHH Foam Systems
    Produces 700 square feet of cured foam at a 1" thickness
    The Hy-Flo Systems are a Class I foam
    $1,279.00
    Versi-Foam - System 33 HFO Formula
    RHH Foam Systems
    Produces 396 square feet of cured foam at a 1" thickness, or 33 cubic feet
    HFO Formula
    $1,260.00
    Versi-Foam - System 33 High Density Foam
    RHH Foam Systems
    Produces 396 square feet of cured foam at a 1" thickness, or 33 cubic feet
    $1,098.00
    Versi-Foam - System 100
    RHH Foam Systems
    Portable, disposable, open-cell spray foam kit. This system yields 1200 square feet of cured foam at a 1” thickness, or 100 cubic feet.
    $1,098.00
    Versi-Foam - System 50: LOW GWP (HFO) FORMULA
    RHH Foam Systems
    2-part system produces 600 square feet of cured foam at a 1” thickness, or 50 cubic feet.
    $1,089.00
    Versi-Foam - System 50
    RHH Foam Systems
    2-part system produces 600 square feet of cured foam at a 1” thickness, or 50 cubic feet.
    $1,019.00
    Versi-Foam - System 15: LOW GWP (HFO) FORMULA
    RHH Foam Systems
    For Customers shipping to: California, Colorado, Delaware, Maine, Maryland, Massachusetts, New Jersey, New York, Rhode Island, Vermont, Virginia, & Washington
    2-part system produces 198 square feet of cured foam at a 1” thickness, or 16.5 cubic feet.
    $549.00
    Versi-Foam - System 15
    RHH Foam Systems
    2-part system produces 198 square feet of cured foam at a 1” thickness, or 16.5 cubic feet.
    $365.00
    ( 2 )
    Versi-Foam - System 9
    RHH Foam Systems
    Produces 108 square feet of cured foam at a 1" thickness, or 9 cubic feet.
    Available in Class I formula only.
    $319.00
    Versi-Foam - System 9 LOW GWP
    RHH Foam Systems
    Produces 108 square feet of cured foam at a 1" thickness, or 9 cubic feet.
    Available in Class I formula only.
    $319.00
    Versi-Foam - 16 lbs. Cylinder Versi-Tite
    RHH Foam Systems
    Versi-Foam 16 lbs Cylinder Versi-Tite
    Please note, the new hose attachment is white not yellow.
    $257.25 3-4 Week Lead Time
    Versi-Foam - Metal Dispensing Gun
    RHH Foam Systems
    Versi-Tite Gun - allows for more control over chemical flow and caulking bead size
    $49.00
    Versi-Foam - System 1
    RHH Foam Systems
    Produces 12 square feet of cured foam at 1" thickness, or one cubic foot
    Density 1.75 pcf
    $45.00
    Versi-Tite - 24 oz Window and Door
    RHH Foam Systems
    One component polyurethane foam sealant specifically formulated for filling, insulating, and sealing around windows and doors to provide a full cavity fill without warping or bowing of frames.
    $12.79
    Versi-Foam - 16 oz. Cleaning Solvent
    RHH Foam Systems
    Versi-Tite Gun Cleaning Solvent. 16 oz. can
    $6.98

VERSI-FOAM® SYSTEMS BY RHH FOAM SYSTEMS STANDARD SYSTEMS

This spray foam insulation product is recommended for most commercial and industrial applications. Ideal for air-sealing, insulating and condensation control.

FLAME RETARDANT (FR) SYSTEMS

These systems have added flame retardants which reduce the flame spread and smoke development of the foam. Suitable for insulating inhabited buildings, including residential applications or any applications in which flammability is a concern. Classified as Class I in accordance with ASTM E-84.


ABOUT CLOSED CELL SPRAY FOAM

Versi-Foam® 2 lb closed cell spray foam insulation kits are available in two different formulations: Standard Formula and Class I (flame-retardant) Formula. The Standard Formula provides an R-value of 7.7 at a one-inch thickness. Recommended for most commercial and industrial applications, the Standard Formula is ideal for air sealing, wall or ceiling insulation, condensation control, sound dampening, structural enhancement, tank and pipe insulation, roof repair, marine flotation, truck/trailer insulation, sculpting and molding, pool and spa insulation, and much more.

The Class I (flame-retardant) Formula provides an R-value 6.7 at a one-inch thickness. Classified as Class I in accordance with ASTM E-84, these flame-retardant kits will limit the flame spread and smoke development if exposed to a fire. Class I closed cell spray foam kits are recommended for use in inhabited buildings, including residential applications or any application in which flammability is a concern. Always consult your local building codes to determine if a flame-retardant product is required for your application.

All of our Class I kits are manufactured with an anti-microbial formula that stops mold from growing on the surface of the foam. All Versi-Foam® products are naturally mold resistant, but the added anti-microbial element provides a safeguard against the growth of the five most common types of fungi found in homes.

ABOUT OPEN CELL SPRAY FOAM KITS

Versi-Foam® open cell foam kits have a density of approximately 0.75 pounds per cubic foot. It is 92% open cell and has an insulation R-value of 4, lower than the other Versi-Foam systems, but still superior to some of the other commonly used insulation materials. The appeal of this product is its high expansion rate. Less foam is needed during application which makes it more cost effective.

Open cell Versi-Foam® kits are particularly dependent on temperature. The yield of open cell products will be greatly reduced in cooler temperatures. In order to fully expand, the open cell foam must utilize heat from the exothermic chemical reaction created when the two chemicals mix - in essence building off of its own heat reaction to reach its full expansion potential. The heat reaction is greater the thicker the foam is applied which helps the expansion. For this reason, open cell Versi-Foam® kits should never be applied in less than 2" passes. Even in the warmest temperatures, the open cell product should NEVER be used in "flash spray" (i.e. less than 2") applications, as yield will be GREATLY reduced.

These systems are best suited for residential roof deck applications (unvented attics, cathedral ceilings, and garage roofs). Some areas of the country (particularly Southern Regions) require open cell foam sprayed along the underside of the roof deck. In the presence of moisture, this low-density foam will dissipate the moisture quicker than closed cell foam. Open cell foam should be installed at a 2" thickness for air sealing applications.

It is also well suited for exterior wall applications where one inch of closed cell foam is applied to the exterior sheathing and then filled with open cell foam. Please note that a vapor retardant would be required on the warm side of the building envelope when installing closed cell foam in conjunction with low density foam due to the open cell content.

https://www.rhhfoamsystems.com/faq/

Empty Cart